IES-A1062FX Series - 8 port unmanaged switch
6x10/100Base-T(X) and 2x100Base-FX, 10/100/1000Base-T(X), 1000Base-SX or 1000Base-LX ports with wide operating temperature range from -40 to 70°C and C1D2/ATEX certified.
- C1D2 and ATEX compliant for harsh industrial environments application
- IES-A1062FX series provide 6x10/100Base-T(X) and 2x100Base-FX fiber ports
- Triple redundant DC power inputs of terminal block and power jack
- Support auto-negotiation and auto-MDI/MDI-X
- Support store and forward transmission
- Support flow control
- Rigid IP-30 aluminum housing design
- DIN-Rail and wall mounting enabled
Physical Ports | ||
10/100Base-T(X) Ports in RJ45 Auto MDI/MDIX |
6 | |
Fiber Ports Number | 2 | 2 |
Fiber Ports Standard | 100Base-FX | 100Base-FX |
Fiber Mode | Multi-mode | Single-mode |
Fiber Diameter (μm) |
62.5/125 μm |
9/125 μm |
Fiber Optical Connector |
SC | SC |
Typical Distance (km) | 2 km | 30 km |
Wavelength (nm) | 1310 nm | 1310 nm |
Max. Output Optical Power (dBm) |
-14 dBm | -8 dBm |
Min. Output Optical Power (dBm) |
-23.5 dBm | -15 dBm |
Max. Input Optical Power (Saturation) |
0 dBm | 0 dBm |
Min. Input Optical Power (Sensitivity) |
-31 dBm | -34 dBm |
Link Budget (dB) | 7.5 dB | 19 dB |
Technology | ||
Ethernet Standards |
IEEE 802.3 for 10Base-T |
|
MAC Table | 8192 MAC addresses | |
Processing | Store-and-Forward | |
LED Indicators | ||
Power Indicator | Green : Power LED x 3 | |
Fault Indicator | Amber : Indicates PWR1 or PWR2 failure occurred | |
10/100Base-FX RJ45 Port Indicator | Green for port Link/Act. Amber for Duplex/Collision | |
10/100/1000Base-T(X) / Fiber Port Indicator |
Green for port Link/Act. Amber for Link | |
Power | ||
Redundant Input Power |
Triple DC inputs : |
|
Power Consumption (Typ.) | 8 Watts | 8 Watts |
Overload Current Protection | Present | |
Reverse Polarity Protection | Present on terminal block | |
Physical Characteristics | ||
Enclosure | IP-30 | |
Dimensions (W x D x H) | 52(W) x 106.1(D) x 144.3(H) mm (2.05x4.18x5.68 inch.) | |
Weight (g) | 680 g | 680 g |
Environmental | ||
Storage Temperature | -40 to 85°C (-40 to 185°F) | |
Operating Temperature | -40 to 70°C (-40 to 158°F) | |
Operating Humidity | 5% to 95% Non-condensing | |
Regulatory Approvals | ||
EMI | FCC Part 15, CISPR (EN55022) class A | |
EMS | IEC61000-4-2 (ESD), IEC61000-4-3 (RS), IEC61000-4-4 (EFT), IEC61000-4-5 (Surge), IEC61000-4-6 (CS), IEC61000-4-8, IEC61000-4-11 | |
Shock | IEC60068-2-27 | |
Free Fall | IEC60068-2-32 | |
Vibration | IEC60068-2-6 | |
Safety | EN60950, UL508 (E331061), UL/cUL Class 1 Division 2 Group A/B/C/D, ATEX Class 1 Zone 2 | |
Warranty | 5 years |